Condition 3 was previously discharged (LA08/2024/1432/DC) The development hereby permitted shall not commence until eit…

Northern Ireland Electricity Plc Northern Ireland Electricity 4 Annagh Drive Craigavon BT63 5QJ
Reference
LA08/2025/1287/DC
Status
Decided
Application type
Discharge of Condition
Location
Northern Ireland Electricity Plc Northern Ireland Electricity 4 Annagh Drive Craigavon BT63 5QJ
Council
Armagh City Banbridge and Craigavon Borough Council
Received
15 Oct 2025
Added
15 Oct 2025
Last updated
18 Mar 2026

Full proposal: Condition 3 was previously discharged (LA08/2024/1432/DC) The development hereby permitted shall not commence until either suitably informed risk assessments produced in accordance with LCRM guidance and/or a detailed remediation strategy for the underground fuel storage tank(s) and fuel dispensing infrastructure has been provided. The remediation strategy must be in line with current Guidance for Pollution prevention (GPP 2 and GPP 27) and the Pollution Prevention Guidance (PPG27). This strategy must be submitted in writing and agreed with the Planning Authority and should identify all the remedial objectives/criteria and the measures which are proposed to mitigate them (including maps/plans showing the remediation design implementation plan detailing timetable of works remedial criteria monitoring program etc). Reason: Protection of environmental receptors and human health to ensure the site is suitable for use. However the Contractor has proposed an alternative solution to the removal of the underground fuel tanks. Instead of removing the underground fuel tanks as previously advised the specialist subcontractor (Baltor Systems) has proposed the following alternative methodology: Diesel tank Decommissioning Draining of the existing suction lines degassing and disconnection from the diesel pump. Disconnection of all mains cables from the 2No. Old Pumps and Fuel Management System removal and disposal of same to facilitate the demolition of the old pump house. Removal of all pipework from the underground diesel tank and removal of tank lid to give access for cleaning and concrete foaming. Removal of all fuel residues and sludge from the underground tank thoroughly washing same with vacuum tanker and degassing in preparation for concrete foaming. Darafil Concrete Foam Filling of tank (assumed to be 16 000 litres) with concrete foam overflowing same into the manhole void and issuing a decommissioning certificate. Our Environmental Consultant's comments are as follows: From: Cove Environmental Consulting With regards to this issue the retaining of the tanks on site – subject to the correct decommissioning works – would be an acceptable alternative to the removal of the tank. The remedial design report noted the tanks would be removed however the key element is the testing around and below the level of the tank itself so if this is still carried out then we can validate the remediation of the tank – i.e. we will be able to show that there is no contamination present in the ground immediately around / below the tank and the source of any future contamination (the tank) has been dealt with. This can all be outlined in the validation report after the works are complete. If the intention is to retain the tank then we would recommend that sampling is undertaken both before and after the decommissioning work – the “before” round will confirm that no contamination is present (as if it is then the tank may actually have to be removed to deal with it) and “after” to ensure that no contamination is caused by the remedial works themselves.

Planning history at this location

9 other applications recorded at or next to this site.

  • LA08/2026/0976/A VALID
    Erection of 2no illuminated wall mounted signs on building facade and 2no free standing totem signs within site curtilage
    Northern Ireland Electricity 4 Annagh Drive Portadown Craigavon BT63 5QJ · 21 Sept 2026
  • LA08/2025/0317/S54 Approved
    Replacement office buildings - A Section 54 application to amend Conditions 2 and 7 of LA08/2023/3029/F Condition 2 No development shall commence until the tem…
    Northern Ireland Electricity 4 Annagh Drive Carn Industrial Estate Craigavon BT63 5QJ · 12 Mar 2025
  • LA08/2024/1432/DC Decided
    Discharge of condition 3 of LA08/2023/3029/F Detailed remediation strategy for the underground fuel storage tank(s) and fuel dispensing infrastructure
    Northern Ireland Electricity 4 Annagh Drive Tarsan Portadown BT63 5QJ · 4 Dec 2024
  • LA08/2023/3029/F Approved
    Demolition of existing NIE offices and associate mobile units with the erection of a replacement office building with new security hut and cycle shelter. Works…
    Northern Ireland Electricity Carn Industrial Estate 4 Annagh Drive Craigavon BT63 5QJ · 22 Nov 2023
  • LA08/2021/1022/F Granted
    Application Proposed for variation to Condition 7 on LA08/2020/1455/F (Erection of a replacement office building)- removing the requirement for hard surface wo…
    NIE Networks Ltd 4 Annagh Drive Carn Industrial Estate Craigavon BT63 5QJ · 23 Jun 2021
  • LA08/2020/1455/F Granted
    Proposed demolition of existing NIE offices and associated mobile units with the erection of a replacement office building. Works to include associated landsca…
    NIE Networks Ltd Carn Industrial Estate 4 Annagh Drive Craigavon BT63 5QJ · 5 Nov 2020
  • N/2005/0793/F Granted
    Erection of Wind Turbine
    NIE Carn Industrial Estate Portadown · 25 Jul 2005
  • N/2004/1105/F Withdrawn
    Addition of 3no. UMTS antennae and associated cabins
    Energis Radio Base Station Annagh Drive Carn Industrial Estate Portadown · 11 Oct 2004
  • N/1989/0587 Granted
    Radio Mast (30.5 Metres High)
    NORTHERN IRELAND ELECTRICITY AREA OFFICE CARN INDUSTRIAL ESTATE PORTADOWN · 18 Jul 1989

Recent applications nearby

  • LA08/2026/0938/F VALID
    Erection of extension to the rear of the premises for additional storage purposes retention of cold room store to rear of premises and retention of extended re…
    34 Seagoe Industrial Estate Portadown Craigavon BT63 5QD · 2 Oct 2026
  • LA08/2025/1562/F SITE INSPECTED
    Widening of Almac Way to include a right hand exit lane onto Seagoe Road. Amendments to existing estate roads and footpaths. Provision of pedestrian crossing p…
    130 metres north of 13 Seagoe Industrial Estate Seagoe Road Portadown · 1 Jun 2026
  • LA08/2025/1470/F SITE INSPECTED
    Provision of surface car parking landscaping and lighting; culverting of watercourse; and provision of access into site from Breagh Drive
    Lands adjacent and east of Breagh Drive (Immediately south and east of Cido Business Complex Carn Road) Carn… · 12 May 2026
  • LA08/2025/1469/F SITE INSPECTED
    Provision of surface car parking landscaping and lighting. Erection of new security hut. Retention of access with alterations into site from Breagh Drive
    Lands adjacent and east of Breagh Drive (80 metres south west of no.1 Annagh Drive) Carn Industrial Estate · 12 May 2026
  • LA08/2025/1449/F SITE INSPECTED
    Demolition of existing single storey lab building located on eastern area of site (building B1A); Erection of new 4 storey building for the provision of resear…
    Lands immediately north of Almac Group Ltd 20 (building B20) Seagoe Industrial Area (including building B1A)… · 11 May 2026
  • LA08/2026/0176/F Approved
    Ground Floor Bedroom & Shower Room Rear Extension & Level Access to Front Door
    260 Kernan Hill Manor Portadown Craigavon BT63 5WU · 23 Feb 2026
  • LA08/2026/0154/A CONSENT GRANTED
    Illuminated totem sign 2no. illuminated signs and 7no. non illuminated way finding signs.
    Diviny Drive / Carn Road junction 40 metres north east of no.2 Diviny Drive Portadown Craigavon BT63 5WE · 16 Feb 2026
  • LA08/2025/1467/F SITE INSPECTED
    Provision of surface car parking paved pedestrian footpath and gate soft landscaping site security fencing lighting and pedestrian gate.
    Opposite and 80 metres NE of 50 Seagoe Industrial Area Portadown Craigavon BT63 5QE · 15 Jan 2026