Erection of 38 residential units - Variation of Conditions 7 and 10 of Planning Approval LA06/2018/0265/F from Conditio…
- Reference
- LA06/2023/1345/F
- Status
- Approved
- Application type
- Full
- Location
- 62-64 South Street Newtownards
- Council
- Ards and North Down Borough Council
- Received
- 10 Jan 2023
- Added
- 10 Jan 2023
Full proposal: Erection of 38 residential units - Variation of Conditions 7 and 10 of Planning Approval LA06/2018/0265/F from Condition 7 - All remedial measures as detailed in Mason Evans report P17-124 ‘Remedial Strategy Assessment’ dated June 2017 shall be fully implemented and a verification report must be submitted in writing for approval by Ards and North Down Borough Council prior to the occupation of the development. The verification report should be completed by competent persons in accordance with the Model Procedures for the Management of Land Contamination (CLR11). The verification report should present all the remediation and monitoring works undertaken and demonstrate the effectiveness of the works in managing all the risks and achieving the remedial objectives. To All remedial measures as detailed in Cove Environmental Consulting Ltd report “Revised Remedial Design Report” dated November 2022 shall be fully implemented and a verification report shall be submitted to and agreed in writing by the Council prior to the occupation of the development. The verification report shall be completed by competent persons in accordance with the Model Procedures for the Management of Land Contamination (CLR11). The verification report shall present all the remediation and monitoring works undertaken and demonstrate the effectiveness of the works in managing all the risks and achieving the remedial objectives. Condition 10 A Verification Report must be submitted in writing for approval by Ards and North Down Borough Council prior to the occupation of the proposed development. This report must demonstrate that the remediation measures outlined in the report titled Remedial Strategy Assessment Lands at Castlebawn South Street Newtownards prepared by Mason Evans referenced P17-124 and dated June 2017 have been fully implemented. The Verification Report shall demonstrate the successful completion of remediation works and that the site is now fit for end-use (Residential with Plant Uptake). It must demonstrate that the identified potential pollutant linkages are effectively broken. The Verification Report shall be in accordance with current best practice and guidance as outlined by the Environment Agency. In particular this Verification Report must demonstrate that: (a) The final site layout shall be as per Drawing 02A bearing the Council's date stamp 20 February 2019 confirming areas of hardstanding roadways parking areas footpaths etc. (b) The emplacement of a 1m thick capping layer across all gardens comprising: -a geotextile membrane (or equivalent) at the base of the capping layer which should be water permeable rot proof chemically resistant and have a high tensile strength. Parallel layers should be suitably secured or overlapped by at least 0.2m. -A capillary layer comprising of at least 300mm of granular material overlain by a total of 700mm of demonstrably proven suitable subsoil and top soil overlying the geotextile membrane to be completed across all garden areas. -The emplacement of a 0.6m thick capping layer across all landscaped areas comprising: -The emplacement of a geotextile membrane (or equivalent) at the base of the capping layer which should be water permeable rot proof chemically resistant and have a high tensile strength. Parallel layers should be suitably secured or overlapped by at least 0.2m. -A layer comprising of at least 600mm of demonstrably proven suitable clean gravel/ subsoil and top soil overlying the geotextile membrane to be completed across all landscaped areas. -All soils re-used or brought on the site to create the capping layer must be accompanied by traceability documentation and shall be demonstrably proven to be suitable for the end use. (c) The specification and details of the installation (including photographs) of the barrier membrane. The membrane shall be certified to be both VOC and vapour resistant and verified in accordance with CIRIA C735. (d) documented evidence shall be provided (to include as a minimum photographs and analytical soil data) of the extent and depth of all excavations to demonstrate that all residual impacts on the site soils has been removed. The report shall also confirm that the remaining soils (or base and side-walls of all excavations) are suitable for residential with plant uptake end use scenario. (e) All material brought on to the site for use to backfill excavations has been accompanied by traceability documentation and shall be demonstrably proven to be suitable for the end use. To A Verification Report shall be submitted to and approved in writing by the Council prior to the occupation of the proposed development. This report shall demonstrate that the remediation measures outlined in the report titled Revised Remedial Design Report date November 2022 have been fully implemented.
Planning history at this location
15 other applications recorded at or next to this site.
- LA06/2024/0640/F Approved
6 no. dwellings (change of house type of units 20-23 and 26-27 of approval LA06/2021/1086/F) with associated landscaping and car parking.
- LA06/2024/0466/DC CONDITION PARTIALLY DISCHARGED
Discharge of condition 4 & 6 of planning approval LA06/2023/1345/F which states .... All remedial measures as detailed in Cove Environmental Consulting Ltd rep…
- LA06/2023/1553/DC CONDITION PARTIALLY DISCHARGED
Discharge of Condition 13 of Planning Approval LA06/2021/1086/F which states 'The long-term management and maintenance of the open space as indicated on Drawin…
- LA06/2023/1472/DC CONDITION PARTIALLY DISCHARGED
Discharge of Condition 16 of Planning Approval LA06/2018/0265/F which states The long-term management and maintenance of the open space as indicated on Drawing…
- LA06/2022/0760/DC Approved
Discharge of Condition of 5 and 12 of Planning Application LA06/2018/0265/F which state - 5. The appointed contractor must submit a final construction environm…
- LA06/2021/1086/F Granted
31no. dwellings (change of house type to units 1-23 of Planning Approval X/2014/0604/F and Units 32-48 and 53 (change of curtilage only at site 53) of Planning…
- LA06/2020/0561/DC Granted
Discharge of Condition of planning Approval X/2014/0604/F 8. A piling risk assessment must be submitted in writing for approval by Ards and North Down Borough…
- LA06/2020/0560/DC Granted
Discharge of Condition of planning Approval LA06/2018/0265/F 8. A piling risk assessment must be submitted in writing for approval by Ards and North Down Borou…
- LA06/2020/0424/DC Granted
Discharge of Conditions 2 and 4 of Planning Approval X/2014/0604/F which state as follows: Condition 2 - 'No site works of any nature or development shall take…
- LA06/2020/0425/DC Granted
Discharge of Conditions 2 and 4 of Planning Approval LA06/2018/0265/F which states: Condition 2 - ' No site works of any nature or development shall take place…
- LA06/2018/0265/F Granted
Demolition of derelict properties and the construction of 38no. residential units consisting of 26no. houses and 12no. apartments with associated car parking a…
- X/2014/0604/F Granted
Demolition of derelict properties and erection of 44 townhouses and 3 apartments
- X/2007/0930/F Granted
Demolition of existing warehouse and erection of residential development comprising 162 No. apartments with associated car parking and landscaping (Amended sch…
- X/2005/1255/O Withdrawn
Demolition of Existing Buildings and Erection of Residential Development
- X/1977/0508 Granted
WAREHOUSE STORAGE
Recent applications nearby
- LA06/2026/0899/F CONSULTATION(S) ISSUED
Change-of-use from dwelling to short-term holiday let accommodation and associated in-curtilage illuminated signage to front of property
- LA06/2026/0894/LBC CONSULTATION(S) ISSUED
Demolition of the partially standing remains of a terrace and reconstruction of 8no. dwellings to replace former terrace housing together with 1no. additional…
- LA06/2026/0895/F CONSULTATION(S) ISSUED
Demolition of the partially standing remains of a terrace and reconstruction of 8no. dwellings to replace former terrace housing together with 1no. additional…
- LA06/2026/0823/LBC CONSULTATION(S) ISSUED
1x sign on existing totem and 2x signs on gable wall
- LA06/2026/0821/A CONSULTATION(S) ISSUED
1x sign on existing totem and 2x signs on gable wall
- LA06/2026/0873/DC CONSULTATION(S) ISSUED
Discharge of Condition 15 of previously approved application LA06/2023/2434/F which states - On completion of the remediation and prior to the occupation of an…
- LA06/2026/0824/F SITE INSPECTED
Installation of storage container on concrete slab for secure file storage with covered canopy to existing mental health unit.
- LA06/2026/0795/F SITE INSPECTED
5no. Dwellings (Change of house type to that approved under LA06/2024/0926/F).